False lumen ejection fraction predicts growth in type B aortic dissection: preliminary results.


ABSTRACT:

Objectives

Current risk assessment strategies in type B aortic dissection are focused on anatomic parameters, although haemodynamic abnormalities that result in false lumen (FL) pressurization are thought to play a significant role in aortic growth. The objective of this study was to evaluate blood flow of the FL using 4D flow magnetic resonance imaging (MRI) and identify haemodynamic and anatomic factors that independently predict the rate of aortic growth.

Methods

Patients with dissection of the descending thoraco-abdominal aorta (n = 18) were enrolled in a prospective observational study and underwent 4D flow MRI for haemodynamic assessment of the entry tear and FL. Anatomic parameters were obtained by magnetic resonance angiography and baseline computed tomography. False