Unknown

Dataset Information

Fully automated treatment planning for MLC-based robotic radiotherapy.


ABSTRACT:

Purpose

To propose and validate a fully automated multicriterial treatment planning solution for a CyberKnife® equipped with an InCiseTM 2 multileaf collimator.

Methods

The AUTO BAO plans are generated using fully automated prioritized multicriterial optimization (AUTO MCO) of pencil-beam fluence maps with integrated noncoplanar beam angle optimization (BAO), followed by MLC segment generation. Both the AUTO MCO and segmentation algorithms have been developed in-house. AUTO MCO generates for each patient a single, high-quality Pareto-optimal IMRT plan. The segmentation algorithm then accurately mimics the AUTO MCO 3D dose distribution, while considering all candidate beams simultaneously, rather than replicating the fluence maps. Pencil-beams, segment dose deposit

SUBMITTER: Schipaanboord BWK 

PROVIDER: S-EPMC8457110 | biostudies-literature | 2021 Aug

REPOSITORIES: biostudies-literature