Assessment of a Multiplex LAMP Assay (Eazyplex® CSF Direct M) for Rapid Molecular Diagnosis of Bacterial Meningitis: Accuracy and Pitfalls.


ABSTRACT: Background: Automated molecular panels are attractive tools for improving early meningitis diagnosis. This study assessed the Eazyplex® CSF direct M panel (EP), a multiplex real-time Loop-Mediated Isothermal Amplification assay. Methods: From December 2016 to December 2019, cerebrospinal fluid (CSF) samples were routinely tested with the EP V1.0. CSF parameters and microbiological and clinical data were retrospectively collected. Results: Out of 230 CSF samples, the EP yielded positive, negative, and invalid results for 32 (13.9%) (16 N. meningitidis, nine S. pneumoniae, two S. agalactiae, two E. coli, two H. influenzae, one L. monocytogenes), 182 (79.1%), and 16 (7%) samples, respectively. Among the positive samples, 14 (44%) remained negative in culture (antibiotic therapy before lumbar