Ontology highlight
ABSTRACT: Background
Point-of-care ultrasound (POCUS) has been recognized as an essential skill across medicine. However, a lack of reliable and streamlined POCUS assessment tools with demonstrated validity remains a significant barrier to widespread clinical integration. The ultrasound competency assessment tool (UCAT) was derived to be a simple, entrustment-based competency assessment tool applicable to multiple POCUS applications. When used to assess a FAST, the UCAT demonstrated high internal consistency and moderate-to-excellent inter-rater reliability. The objective of this study was to validate the UCAT for assessment of a four-view transthoracic cardiac POCUS.Results
Twenty-two trainees performed a four-view transthoracic cardiac POCUS in a simulated environment while being a
SUBMITTER: Bell C
PROVIDER: S-EPMC8476706 | biostudies-literature | 2021 Sep
REPOSITORIES: biostudies-literature