ABSTRACT: Background
Simultaneous left ventricular (LV) and aortic (Ao) pressure gradient assessment has been rendered challenging since the recall of the Langston catheter. Here we describe a simple method for simultaneous LV and Ao pressure gradient assessment using a Swan-Ganz catheter.Case summary
We describe two cases where assessment of simultaneous left ventricle and Ao valve gradients was done using a Swan-Ganz catheter to assess the degree of Ao stenosis and dynamic LV outflow obstruction.Discussion
Using Swan-Ganz catheter assessment of simultaneous left ventricle and Ao valve gradients can simplify the procedure with reduced cost and increased patient safety.
SUBMITTER: Agarwal N
PROVIDER: S-EPMC8495136 | biostudies-literature | 2021 Oct
REPOSITORIES: biostudies-literature
Agarwal Nayan N Rastogi Ujjwal U Mahmoud Ahmed N AN Bhatt Deepak L DL
European heart journal. Case reports 20210924 10
<h4>Background</h4>Simultaneous left ventricular (LV) and aortic (Ao) pressure gradient assessment has been rendered challenging since the recall of the Langston catheter. Here we describe a simple method for simultaneous LV and Ao pressure gradient assessment using a Swan-Ganz catheter.<h4>Case summary</h4>We describe two cases where assessment of simultaneous left ventricle and Ao valve gradients was done using a Swan-Ganz catheter to assess the degree of Ao stenosis and dynamic LV outflow obs ...[more]