Open-Source Automatic Biomarker Measurement on Slit-Lamp Photography to Estimate Visual Acuity in Microbial Keratitis.


ABSTRACT:

Purpose

To assess clinical applicability of automatic image analysis in microbial keratitis (MK) by evaluating the relationship between biomarker measurements on slit-lamp photography (SLP) and best-corrected visual acuity (BCVA).

Methods

Seventy-six patients with MK with SLP images and same-day logarithm of the minimum angle of resolution (logMAR) BCVA were evaluated. MK biomarkers (stromal infiltrate, white blood cell infiltration, corneal edema, hypopyon, epithelial defect) were segmented manually by ophthalmologists and automatically by a novel, open-source, deep learning-based segmentation algorithm. Five measurements (presence, maximum width, total area, proportion of the corneal limbus area affected, centrality) were calculated. Correlations between the measurements a