Quantifying microcalcification activity in the thoracic aorta.


ABSTRACT:

Background

Standard methods for quantifying positron emission tomography (PET) uptake in the aorta are time consuming and may not reflect overall vessel activity. We describe aortic microcalcification activity (AMA), a novel method for quantifying 18F-sodium fluoride (18F-NaF) uptake in the thoracic aorta.

Methods

Twenty patients underwent two hybrid 18F-NaF PET and computed tomography (CT) scans of the thoracic aorta less than three weeks apart. AMA, as well as maximum (TBRmax) and mean (TBRmean) tissue to background ratios, were calculated by two trained operators. Intra-observer repeatability, inter-observer repeatability and scan-rescan reproducibility were assessed. Each 18F-NaF quantification method was compared to validated cardiovascular risk scores.

Results

Aortic microcalcification activity demonstrated excellent intra-observer (intraclass correlation coefficient 0.98) and inter-observer (intraclass correlation coefficient 0.97) repeatability with very good scan-rescan reproducibility (intraclass correlation coefficient 0.86) which were similar to previously described TBRmean and TBRmax methods. AMA analysis was much quicker to perform than standard TBR assessment (3.4min versus 15.1min, P<0.0001). AMA was correlated with Framingham stroke risk scores and Framingham risk score for hard cononary heart disease.

Conclusions

AMA is a simple, rapid and reproducible method of quantifying global 18F-NaF uptake across the ascending aorta and aortic arch that correlates with cardiovascular risk scores.

SUBMITTER: Fletcher AJ 

PROVIDER: S-EPMC8497049 | biostudies-literature | 2022 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background</h4>Standard methods for quantifying positron emission tomography (PET) uptake in the aorta are time consuming and may not reflect overall vessel activity. We describe aortic microcalcification activity (AMA), a novel method for quantifying <sup>18</sup>F-sodium fluoride (18F-NaF) uptake in the thoracic aorta.<h4>Methods</h4>Twenty patients underwent two hybrid <sup>18</sup>F-NaF PET and computed tomography (CT) scans of the thoracic aorta less than three weeks apart. AMA, as well  ...[more]

Similar Datasets

| S-EPMC9311465 | biostudies-literature
2025-02-18 | PXD060700 | Pride
| S-EPMC9671295 | biostudies-literature
2016-11-08 | GSE88421 | GEO
| S-EPMC8350782 | biostudies-literature
| S-EPMC2824651 | biostudies-other
2017-03-12 | GSE96479 | GEO
2017-03-12 | GSE96475 | GEO
2017-03-12 | GSE96467 | GEO
2025-01-14 | GSE286699 | GEO