ABSTRACT: Background
To evaluate whether MicroPure imaging, an ultrasound (US) image-processing technique with computer-aided analysis, can quantitatively detect crystal dissolution during urate-lowering therapy (ULT) in gout.Methods
This was a prospective study of gout patients requiring ULT. The first metatarsophalangeal joints were examined using US and MicroPure before and after 3 months of ULT. Elementary lesions of gout, including the double contour sign (DCS), aggregates, tophi, erosion, and other US features were recorded at baseline and 3 months. MicroPure imaging features were automatically calculated by a self-developed software. Patients were divided into goal-achieved and goal-not-achieved groups according to their urate levels at 3 months. The US and MicroPure imaging features of the two groups were analyzed at baseline and 3 months.Results
A total of 55 consecutive patients were enrolled (25: goal-achieved group; 30: goal-not-achieved group). US findings demonstrated that the power Doppler signal grade decreased at 3 months, regardless of the group (both P<0.05). From baseline to 3 months, tophi size and the DCS reduced in the goal-achieved group (both P<0.05), while the US aggregate features showed no difference (P=0.250). However, on the MicroPure imaging, the number and density of aggregates at 3 months decreased in the goal-achieved group (both P<0.05). There were no significant changes at 3 months in any of the MicroPure imaging features in the goal-not-achieved group (all P>0.05).Conclusions
In comparison with B-mode US, computer-aided MicroPure imaging can sensitively and quantitatively detect aggregate dissolution during effective ULT after only 3 months of treatment.
SUBMITTER: Wang Q
PROVIDER: S-EPMC8506744 | biostudies-literature | 2021 Sep
REPOSITORIES: biostudies-literature

Wang Qiao Q Bao Hui H Guo Le-Hang LH Jin Feng-Shan FS Li Xiao-Long XL Yin Hao-Hao HH Yue Wen-Wen WW Zhu An-Qi AQ Wang Li-Fan LF Sun Li-Ping LP Xu Hui-Xiong HX
Annals of translational medicine 20210901 18
<h4>Background</h4>To evaluate whether MicroPure imaging, an ultrasound (US) image-processing technique with computer-aided analysis, can quantitatively detect crystal dissolution during urate-lowering therapy (ULT) in gout.<h4>Methods</h4>This was a prospective study of gout patients requiring ULT. The first metatarsophalangeal joints were examined using US and MicroPure before and after 3 months of ULT. Elementary lesions of gout, including the double contour sign (DCS), aggregates, tophi, ero ...[more]