ABSTRACT: Purpose
The purpose of this study was to discuss the propensity of aerosol and droplet generation during vitreoretinal surgery using high speed imaging amidst the coronavirus disease 2019 (COVID-19) pandemic.Methods
In an experimental set up, various steps of vitreoretinal surgery were performed on enucleated goat eyes. The main outcome measures were visualization, quantification of size, and calculation of aerosol spread.Results
During intravitreal injection, insertion of cannulas, lensectomy, and vitrectomy with both 23 and 25-gauge instruments, with either valved or nonvalved cannulas, aerosols were not visualized which was confirmed on imaging. Although there was no aerosol generation during active fluid air exchange (FAE), there was bubbling and aerosol generat