Tracheal intubation while wearing personal protective equipment in simulation studies: a systematic review and meta-analysis with trial-sequential analysis.


ABSTRACT:

Background

Tracheal intubation in patients with coronavirus disease-19 is a high-risk procedure that should be performed with personal protective equipment (PPE). The influence of PPE on operator's performance during tracheal intubation remains unclear.

Methods

We conducted a systematic review and meta-analysis of simulation studies to evaluate the influence of wearing PPE as compared to standard uniform regarding time-to-intubation (TTI) and success rate. Subgroup analyses were conducted according to device used and operator's experience.

Results

The TTI was prolonged when wearing PPE (eight studies): Standard Mean Difference (SMD) -0.54, 95% Confidence Interval [-0.75, -0.34], p <  0.0001. Subgroup analyses according to device used showed similar findings (direct la

SUBMITTER: Sanfilippo F 

PROVIDER: S-EPMC8556077 | biostudies-literature | 2022 Mar-Apr