Unknown

Dataset Information

0

Artificial Intelligence-Based 3D Angiography for Visualization of Complex Cerebrovascular Pathologies.


ABSTRACT:

Background and purpose

By means of artificial intelligence, 3D angiography is a novel postprocessing method for 3D imaging of cerebral vessels. Because 3D angiography does not require a mask run like the current standard 3D-DSA, it potentially offers a considerable reduction of the patient radiation dose. Our aim was an assessment of the diagnostic value of 3D angiography for visualization of cerebrovascular pathologies.

Materials and methods

3D-DSA data sets of cerebral aneurysms (n CA = 10), AVMs (n AVM = 10), and dural arteriovenous fistulas (dAVFs) (n dAVF = 10) were reconstructed using both conventional and prototype software. Corresponding reconstructions have been analyzed by 2 neuroradiologists in a consensus reading in terms of image quality, injection vessel diameters (vessel diameter [VD] 1/2), vessel geometry index (VGI = VD1/VD2), and specific qualitative/quantitative parameters of AVMs (eg, location, nidus size, feeder, associated aneurysms, drainage, Spetzler-Martin score), dAVFs (eg, fistulous point, main feeder, diameter of the main feeder, drainage), and cerebral aneurysms (location, neck, size).

Results

In total, 60 volumes have been successfully reconstructed with equivalent image quality. The specific qualitative/quantitative assessment of 3D angiography revealed nearly complete accordance with 3D-DSA in AVMs (eg, mean nidus size3D angiography/3D-DSA= 19.9 [SD, 10.9]/20.2 [SD, 11.2] mm; r = 0.9, P = .001), dAVFs (eg, mean diameter of the main feeder3D angiography/3D-DSA= 2.04 [SD, 0.65]/2.05 [SD, 0.63] mm; r = 0.9, P = .001), and cerebral aneurysms (eg, mean size3D angiography/3D-DSA= 5.17 [SD, 3.4]/5.12 [SD, 3.3] mm; r = 0.9, P = .001). Assessment of the geometry of the injection vessel in 3D angiography data sets did not differ significantly from that of 3D-DSA (vessel geometry indexAVM: r = 0.84, P = .003; vessel geometry indexdAVF: r = 0.82, P = .003; vessel geometry indexCA: r = 0.84, P <.001).

Conclusions

In this study, the artificial intelligence-based 3D angiography was a reliable method for visualization of complex cerebrovascular pathologies and showed results comparable with those of 3D-DSA. Thus, 3D angiography is a promising postprocessing method that provides a significant reduction of the patient radiation dose.

SUBMITTER: Lang S 

PROVIDER: S-EPMC8562747 | biostudies-literature | 2021 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Artificial Intelligence-Based 3D Angiography for Visualization of Complex Cerebrovascular Pathologies.

Lang S S   Hoelter P P   Schmidt M M   Strother C C   Kaethner C C   Kowarschik M M   Doerfler A A  

AJNR. American journal of neuroradiology 20210909 10


<h4>Background and purpose</h4>By means of artificial intelligence, 3D angiography is a novel postprocessing method for 3D imaging of cerebral vessels. Because 3D angiography does not require a mask run like the current standard 3D-DSA, it potentially offers a considerable reduction of the patient radiation dose. Our aim was an assessment of the diagnostic value of 3D angiography for visualization of cerebrovascular pathologies.<h4>Materials and methods</h4>3D-DSA data sets of cerebral aneurysms  ...[more]

Similar Datasets

| S-EPMC11653446 | biostudies-literature
| S-EPMC11837989 | biostudies-literature
| S-EPMC10351662 | biostudies-literature
| S-EPMC11544045 | biostudies-literature
| S-EPMC11544092 | biostudies-literature
| S-EPMC10173041 | biostudies-literature
| S-EPMC9247240 | biostudies-literature
| S-EPMC9881077 | biostudies-literature
| S-EPMC9947408 | biostudies-literature
| S-EPMC11784206 | biostudies-literature