Real-time concentration monitoring using a compact composite sensor array for in situ quality control of aqueous formulations.
Ontology highlight
ABSTRACT: Recent advancements have demonstrated the feasibility of refrigerator-sized pharmaceutical manufacturing platforms (PMPs) for integrated end-to-end manufacturing of active pharmaceutical ingredients (APIs) into formulated drug products. Unlike typical laboratory- or industrial-scale setups, PMPs present unique requirements for process analytical technology (PAT) with respect to versatility, flexibility, and physical size to fit into the PMP space constraints. In this proof of principle study, a novel compact composite sensor array (CCSA) combining ultraviolet (UV) and near infrared (NIR) features at four different wavelengths (280, 340, 600, 860 nm) with temperature measuring capability in a 380 × 30 mm housing (length x diameter, 7 mm diameter at the probe head), were evaluated. The resul
SUBMITTER: De la Rosa MVG
PROVIDER: S-EPMC8570044 | biostudies-literature | 2021 Nov
REPOSITORIES: biostudies-literature