Unknown

Dataset Information

Navigated laparoscopic microwave ablation of tumour mimics in pig livers: a randomized ex-vivo experimental trial.


ABSTRACT:

Background

In order to efficiently perform laparoscopic microwave ablation of liver tumours precise positioning of the ablation probe is mandatory. This study evaluates the precision and ablation accuracy using the innovative laparoscopic stereotactic navigation system CAS-One-SPOT in comparison to 2d ultrasound guided laparoscopic ablation procedures.

Methods

In a pig liver ablation model four surgeons, experienced (n = 2) and inexperienced (n = 2) in laparoscopic ablation procedures, were randomized for 2d ultrasound guided laparoscopic or stereotactic navigated laparoscopic ablation procedures. Each surgeon performed a total of 20 ablations. Total attempts of needle placements, time from tumor localization till beginning of ablation and ablation accuracy were analyzed.

SUBMITTER: Thomas MN 

PROVIDER: S-EPMC8599321 | biostudies-literature | 2021 Dec

REPOSITORIES: biostudies-literature