Ontology highlight
ABSTRACT: Objective
Our primary objective was to determine the performance of real-time neuroscience intensive care unit (neuro-ICU) nurse interpretation of quantitative EEG (qEEG) at the bedside for seizure detection. Secondary objectives included determining nurse time to seizure detection and assessing factors that influenced nurse accuracy.Methods
Nurses caring for neuro-ICU patients undergoing continuous EEG (cEEG) were trained using a 1-hour qEEG panel (rhythmicity spectrogram and amplitude-integrated EEG) bedside display. Nurses' hourly interpretations were compared with post hoc cEEG review by 2 neurophysiologists as the gold standard. Diagnostic performance, time to seizure detection compared with standard of care (SOC), and effects of other factors on nurse accuracy were ca
SUBMITTER: Kaleem S
PROVIDER: S-EPMC8610554 | biostudies-literature | 2021 Oct
REPOSITORIES: biostudies-literature