Unknown

Dataset Information

Simply Fabricated Inexpensive Dual-Polymer-Coated Fabry-Perot Interferometer-Based Temperature Sensors with High Sensitivity.


ABSTRACT: We designed simply fabricated, highly sensitive, and cost-effective dual-polymer-coated Fabry-Perot interferometer (DFPI)-based temperature sensors by employing thermosensitive polymers and non-thermosensitive polymers, as well as different two successive dip-coating techniques (stepwise dip coating and polymer mixture coating). Seven sensors were fabricated using different polymer combinations for performance optimization. The experiments demonstrated that the stepwise dip-coated dual thermosensitive polymer sensors exhibited the highest sensitivity (2142.5 pm °C-1 for poly(methyl methacrylate)-polycarbonate (PMMA_PC) and 785.5 pm °C-1 for poly(methyl methacrylate)- polystyrene (PMMA_PS)). Conversely, the polymer-mixture-coated sensors yielded low sensitivities (339.5 pm °C-1 for the poly

SUBMITTER: Salunkhe TT 

PROVIDER: S-EPMC8620928 | biostudies-literature | 2021 Nov

REPOSITORIES: biostudies-literature