Unknown

Dataset Information

The use of oxygen reserve index in one-lung ventilation and its impact on peripheral oxygen saturation, perfusion index and, pleth variability index.


ABSTRACT:

Background

Our goal is to investigate the use of the oxygen reserve index (ORi) to detect hypoxemia and its relation with parameters such as; peripheral oxygen saturation, perfusion index (PI), and pleth variability index (PVI) during one-lung ventilation (OLV).

Methods

Fifty patients undergoing general anesthesia and OLV for elective thoracic surgeries were enrolled in an observational cohort study in a tertiary care teaching hospital. All patients required OLV after a left-sided double-lumen tube insertion during intubation. The definition of hypoxemia during OLV is a peripheral oxygen saturation (SpO2) value of less than 95%, while the inspired oxygen fraction (FiO2) is higher than 50% on a pulse oximetry device. ORi, pulse oximetry, PI, and PVI values were measured conti

SUBMITTER: Sagiroglu G 

PROVIDER: S-EPMC8685494 | biostudies-literature | 2021 Dec

REPOSITORIES: biostudies-literature