ABSTRACT: Purpose
"In-the-bag" placement of an IOL is the Holy Grail for any cataract surgeon. However, in the absence of capsular integrity, alternative surgical options to place the IOL must be sought. We aim to report the clinical outcomes and safety profile of scleral-fixated Akreos AO60 intraocular lens implantation using Gore-Tex suture, combined with pars plana vitrectomy.Methods
This is a single-center, retrospective case series descriptive study. Electronic clinical records of all patients subjected to scleral fixation of a Bausch and Lomb Akreos AO60 IOL combined with pars plana vitrectomy, between April 1, 2017, and August 1, 2021, were reviewed. Data concerning age, sex, laterality, past ophthalmological history, pre- and postoperative best-available visual acuity, surgic
SUBMITTER: Leuzinger-Dias M