Unknown

Dataset Information

0

Assessment of Perioperative Atelectasis Using Lung Ultrasonography in Patients Undergoing Pneumoperitoneum Surgery in the Trendelenburg Position: Aspects of Differences according to Ventilatory Mode.


ABSTRACT:

Background

During robotic gynecologic pneumoperitoneum surgery in the Trendelenburg position, aeration loss leads to perioperative atelectasis. Recently developed ventilator mode pressure-controlled ventilation volume-guaranteed (PCV-VG) mode could provide adequate ventilation with lower inspiratory pressure compared to volume-controlled ventilation (VCV); we hypothesized that PCV-VG mode may be beneficial in reducing perioperative atelectasis via low tidal volume (VT) of 6 mL/kg ventilation during robotic gynecologic pneumoperitoneum surgery in the Trendelenburg position. We applied lung ultrasound score (LUS) for detecting perioperative atelectasis. We aimed to compare perioperative atelectasis between VCV and PCV-VG with a low VT of 6 mL/kg during pneumoperitoneum surgery in the Trendelenburg position using LUS.

Methods

Patients scheduled for robotic gynecologic surgery were randomly allocated to the VCV (n = 41) or PCV-VG group (n = 41). LUS, ventilatory, and hemodynamic parameters were evaluated at T1 (before induction), T2 (10 minutes after induction in the supine position), T3 (10 minutes after desufflation of CO2 in the supine position), and T4 (30 minutes after emergence from anesthesia in the recovery room).

Results

Eighty patients (40 with PCV-VG and 40 with VCV) were included. Demographic data showed no significant differences between the groups. The total LUS has changed from baseline to T4, 0.63 (95% confidence interval [CI], 0.32, 0.94) to 1.77 (95% CI, 1.42, 2.21) in the VCV group and 0.86 (95% CI, 0.56, 1.16) to 1.43 (95% CI, 1.08, 1.78) in the PCV-VG group (P = 0.170). In both groups, total LUS increased significantly compared to the baseline values.

Conclusion

Using a low VT of 6 mL/kg during pneumoperitoneum surgery in the Trendelenburg position, our study showed no evidence that PCV-VG ventilation was superior to VCV in terms of perioperative atelectasis.

Trial registration

Clinical Research Information Service Identifier: KCT0006404.

SUBMITTER: Lee YY 

PROVIDER: S-EPMC8728588 | biostudies-literature | 2021 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Assessment of Perioperative Atelectasis Using Lung Ultrasonography in Patients Undergoing Pneumoperitoneum Surgery in the Trendelenburg Position: Aspects of Differences according to Ventilatory Mode.

Lee Youn Young YY   Han Jong In JI   Kang Bo Kyung BK   Jeong Kyungah K   Lee Jong Wha JW   Kim Dong Yeon DY  

Journal of Korean medical science 20211227 50


<h4>Background</h4>During robotic gynecologic pneumoperitoneum surgery in the Trendelenburg position, aeration loss leads to perioperative atelectasis. Recently developed ventilator mode pressure-controlled ventilation volume-guaranteed (PCV-VG) mode could provide adequate ventilation with lower inspiratory pressure compared to volume-controlled ventilation (VCV); we hypothesized that PCV-VG mode may be beneficial in reducing perioperative atelectasis via low tidal volume (V<sub>T</sub>) of 6 mL  ...[more]

Similar Datasets

| S-EPMC9816202 | biostudies-literature
| S-EPMC5267400 | biostudies-literature
| S-EPMC7458000 | biostudies-literature
| S-EPMC6521399 | biostudies-literature
| S-EPMC6947909 | biostudies-literature
| S-EPMC4355496 | biostudies-literature
| S-EPMC10436464 | biostudies-literature
| S-EPMC5057242 | biostudies-literature
| S-EPMC10163013 | biostudies-literature
| S-EPMC11472628 | biostudies-literature