Unknown

Dataset Information

0

Outcomes of Bicuspid Aortic Valve Thoracic Aorta (4.0-4.5 cm) After Aortic Valve Replacement.


ABSTRACT:

Background

There is little evidence on managing the proximal aorta of 4.0-4.5 cm during aortic valve replacement (AVR) in bicuspid aortic valve patients.

Methods

A total of 431 patients between 1993 and 2019 underwent either an isolated AVR, AVR + concomitant ascending aorta replacement, or aortic root replacement. We divided patients into native root dilation (4.0-4.5 cm, n = 121) vs root control groups (<4.0 cm, n = 238), native ascending dilation (4.0-4.5 cm, n = 50) vs ascending control groups (<4.0 cm, n = 166), or proximal dilation (root or ascending aorta 4.0-4.5 cm, n = 160) and proximal control groups (both root and ascending aorta <4.0 cm, n = 272).

Results

Growth rate was similar between the root dilation and control groups, (both were 0.1 mm/y, P = .56). The ascending dilation group had an aorta growth rate of 0.0 mm/y after AVR or root replacement, which was significantly different from the ascending control group (0.2 mm/y), P = .01. Furthermore, growth rate was similar between the proximal dilation (combined root or ascending dilation) and control group (both were 0.1 mm/y, P = .20). There were only 2 ascending aortic aneurysm repairs after AVR in the whole cohort. The long-term survival was similar between the root or ascending dilation groups vs root or ascending control groups, and between the proximal dilation and control groups. Multivariable Cox regression confirmed aortic root or ascending dilation was not a significant risk factor of long-term mortality.

Conclusions

Our findings supported not replacing a 4.0-4.5 cm proximal thoracic aorta, including aortic root and ascending aorta, at the time of AVR for bicuspid aortic valve patients.

SUBMITTER: Longi F 

PROVIDER: S-EPMC8733045 | biostudies-literature | 2022 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Outcomes of Bicuspid Aortic Valve Thoracic Aorta (4.0-4.5 cm) After Aortic Valve Replacement.

Longi Faraz F   Orelaru Felix F   Clemence Jeffrey J   Naeem Aroma A   Wu Xiaoting X   Yang Bo B  

The Annals of thoracic surgery 20210706 5


<h4>Background</h4>There is little evidence on managing the proximal aorta of 4.0-4.5 cm during aortic valve replacement (AVR) in bicuspid aortic valve patients.<h4>Methods</h4>A total of 431 patients between 1993 and 2019 underwent either an isolated AVR, AVR + concomitant ascending aorta replacement, or aortic root replacement. We divided patients into native root dilation (4.0-4.5 cm, n = 121) vs root control groups (<4.0 cm, n = 238), native ascending dilation (4.0-4.5 cm, n = 50) vs ascendi  ...[more]

Similar Datasets

| S-EPMC10089858 | biostudies-literature
| S-EPMC11142625 | biostudies-literature
| S-EPMC10625967 | biostudies-literature
| S-EPMC6018902 | biostudies-literature
| S-EPMC10894003 | biostudies-literature
| S-EPMC11494546 | biostudies-literature