Unknown

Dataset Information

An equivalent circuit model for localized electroporation on porous substrates.


ABSTRACT: In vitro intracellular delivery is a fundamental challenge with no widely adopted methods capable of both delivering to millions of cells and controlling that delivery to a high degree of accuracy. One promising method is porous substrate electroporation (PSEP), where cells are cultured on porous substrates and electric fields are used to permeabilize discrete portions of the cell membrane for delivery. A major obstacle to the widespread use of PSEP is a poor understanding of the various impedances that constitute the system, including the impedances of the porous substrate and the cell monolayer, and how these impedances are influenced by experimental parameters. In response, we used impedance measurements to develop an equivalent circuit model that closely mimics the behavior of each of

SUBMITTER: Brooks JR 

PROVIDER: S-EPMC8741749 | biostudies-literature | 2022 Mar

REPOSITORIES: biostudies-literature