Continuous 24-h Photoplethysmogram Monitoring Enables Detection of Atrial Fibrillation.
Ontology highlight
ABSTRACT: Aim: Atrial fibrillation (AF) detection is challenging because it is often asymptomatic and paroxysmal. We evaluated continuous photoplethysmogram (PPG) for signal quality and detection of AF. Methods: PPGs were recorded using a wrist-band device in 173 patients (76 AF, 97 sinus rhythm, SR) for 24 h. Simultaneously recorded 3-lead ambulatory ECG served as control. The recordings were split into 10-, 20-, 30-, and 60-min time-frames. The sensitivity, specificity, and F1-score of AF detection were evaluated for each time-frame. AF alarms were generated to simulate continuous AF monitoring. Sensitivities, specificities, and positive predictive values (PPVs) of the alarms were evaluated. User experiences of PPG and ECG recordings were assessed. The study was registered in the Cli
SUBMITTER: Valiaho ES
PROVIDER: S-EPMC8764282 | biostudies-literature | 2021
REPOSITORIES: biostudies-literature
ACCESS DATA