Unknown

Dataset Information

Assessing the reliability and degradation of 10-35 years field-aged PV modules.


ABSTRACT: The objective of this study was to conduct a reliability analysis on photovoltaic (PV) modules from the oldest PV installation site in Pakistan. Four sets of modules; Type A & B (30 years old), Type C (10 years old), and Type D (35 years old) were identified for this analysis. It has been observed that modules have shown degradation after working for a good number of years in the field. Comparing with nameplate data (available for Type B & C only), a drop of 28.68% and 2.99 percentage points (pp) was observed in the output power (Pmax) and efficiency (Eff.) respectively for Type B, while a drop of 22.21% and 4.05 pp was observed in Pmax and Eff. respectively for Type C. A greater drop in ISC and Pmax was observed in Type B, which is attributed to severe browning of EVA in them. While the g

SUBMITTER: Noman M 

PROVIDER: S-EPMC8769327 | biostudies-literature | 2022

REPOSITORIES: biostudies-literature