3-dimensional printing for the diagnosis of left ventricular outflow tract obstruction after mitral valve replacement.


ABSTRACT: The objective of this study was to evaluate the use of the generation of 3D models and 3D prints of complex cases for physicians at the example of an intricate left ventricular outflow tract obstruction (LVOTO). LVOTO is a known complication of mitral valve surgery. A 38-year-old female patient with increasing dyspnoea after mitral valve replacement was referred to our centre. Echocardiography showed a strut of the bioprosthetic heart valve protruding into the left ventricular outflow tract. However, the diagnosis of a LVOTO was difficult based on echocardiography alone. Therefore, we fabricated a physical model of the left ventricular outflow tract, the mitral valve, the aortic valve and the left ventricle. With this physical model in hand, we were able to visualize the LVOTO and to discu

SUBMITTER: Sodian R 

PROVIDER: S-EPMC8782233 | biostudies-literature | 2021 May

REPOSITORIES: biostudies-literature