Project description:Background and study aimDue to the scarcity of specific data on endoscopic ultrasound (EUS)-guided fine-needle biopsies (SharkCore) FNB in the evaluation of pancreatic lesions, we performed a prospective study of the diagnostic performance of EUS SharkCore FNB in patients with pancreatic lesions. The aim of this study was to evaluate the diagnostic accuracy.Patients and methodsSingle-center prospective study of 41 consecutive patients referred for EUS-FNB from October 2015 to April 2016 at our center. EUS-FNB was obtained in a predefined setting regarding the procedure and pathological evaluation. Data regarding demographics, lesion, technical parameters, and diagnostic accuracy were obtained.ResultsThe study included 41 consecutive patients (22 males (54 %); median age 68 years). The average size of the lesions was 28 mm (median: 30 mm). A diagnostic specimen was identified in 40 (98 %) cases during microscopy with an average of 2.4 passes. The route was trans-duodenal in 20 cases (49 %). The histological diagnosis of the specimens was malignant in 29 cases (71 %), benign in 8 (20 %), suspicious in 2 (5 %), atypical in 1 (2 %) and in 1 (2 %) no material for microscopic evaluation was obtained. This led to a diagnostic accuracy of 93 %, sensitivity of 91 % and a specificity of 100 %. 2 cases (5 %) of self-limiting bleeding were observed. The diagnosis at follow up was malignant in 32 (78 %) of the patients.ConclusionsEUS-FNB of pancreatic mass lesions with the SharkCore needle produced specimens with a diagnostic accuracy of 93 %. The procedure was safe and easy to perform, and these data support the use of EUS-FNB in a routine setting.
Project description:Background and aimsSeveral studies have shown the benefits of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) using a Franseen needle for histological assessment. However, studies focusing on pancreatic diseases are limited and the safety of this method has not been well assessed. We aimed to assess the current status and issues of EUS-FNB in the diagnosis of pancreatic diseases.Materials and methodsWe retrospectively reviewed 87 consecutive EUS-FNB specimens using either a 22-gauge Franseen needle (Group A, N = 51) or a conventional 22-gauge fine-needle aspiration needle (Group B, N = 36) for pancreatic diseases, and the diagnostic accuracy and safety were compared. Final diagnoses were obtained based on surgical pathology or a minimum six-month clinical follow-up.ResultsAlthough the diagnostic accuracy for malignancy was 96.1% in Group A versus 88.9% in Group B, with no statistically significant difference (P = 0.19), the median sample area was significantly larger in Group A (4.07 versus 1.31mm2, P < 0.0001). There were no differences between the two needles in the locations from which the specimens were obtained. Adverse events occurred in one case (2%) in Group A (mild pancreatitis) and none in Group B with no statistical significance (P = 0.586). Although there was no case of bleeding defined as adverse events, 2 cases in Group A showed active bleeding during the procedure with increase in the echo-free space, which required CT scanning to rule out extravasation. Eventually, the bleeding stopped spontaneously.ConclusionsGiven its guaranteed ability to obtain core specimens and comparable safety, and although the risk of bleeding should be kept in mind, EUS-FNB using a Franseen needle is likely to become a standard procedure for obtaining pancreatic tissue in the near future.
Project description:BackgroundDiagnostic laparoscopy is often a necessary, albeit invasive, procedure to help resolve undiagnosed peritoneal diseases. Previous retrospective studies reported that EUS-FNA is feasible on peritoneal and omental lesions, however, EUS-FNA provided a limited amount of tissue for immunohistochemistry stain (IHC).AimThis pilot study aims to prospectively determine the effectiveness of EUS-FNB regarding adequacy of tissue for IHC staining, diagnostic rate and the avoidance rate of diagnostic laparoscopy or percutaneous biopsy in patients with these lesions.MethodsFrom March 2017 to June 2018, patients with peritoneal or omental lesions identified by CT or MRI at the King Chulalongkorn Memorial Hospital, Bangkok, Thailand were prospectively enrolled in the study. All Patients underwent EUS-FNB. For those with negative pathological results of EUS-FNB, percutaneous biopsy or diagnostic laparoscopy was planned. Analysis uses percentages only due to small sample sizes.ResultsA total of 30 EUS-FNB passes were completed, with a median of 3 passes (range 2-3 passes) per case. For EUS-FNB, the sensitivity, specificity, PPV, NPV and accuracy of EUS-FNB from peritoneal lesions were 63.6%, 100%, 100%, 20% and 66.7% respectively. Adequate tissue for IHC stain was found in 25/30 passes (80%). The tissues from EUS results were found malignant in 7/12 patients (58.3%). IHC could be done in 10/12 patients (83.3%). Among the five patients with negative EUS results, two underwent either liver biopsy of mass or abdominal paracentesis, showing gallbladder cancer and adenocarcinoma. Two patients refused laparoscopy due to advanced pancreatic cancer and worsening ovarian cancer. The fifth patient had post-surgical inflammation only with spontaneous resolution. The avoidance rate of laparoscopic diagnosis was 58.3%. No major adverse event was observed.ConclusionsEUS-FNB from peritoneal lesions provided sufficient core tissue for diagnosis and IHC. Diagnostic laparoscopy can often be avoided in patients with peritoneal lesions.
Project description:Endoscopic ultrasound (EUS) with fine needle aspiration (FNA) or biopsy (FNB) to diagnose lesions in the gastrointestinal tract is common. Demand for histology sampling to identify treatment-specific targets is increasing. Various core biopsy FNB needles to obtain tissue for histology are currently available, however, with variable (37-97%) histology yields. In this multicenter study, we evaluated performance, safety, and user experience of a novel device (the puncture biopsy forceps (PBF) needle). Twenty-four procedures with the PBF needle were performed in 24 patients with a suspected pancreatic lesion (n = 10), subepithelial lesion (n = 10), lymph node (n = 3), or pararectal mass (n = 1). In 20/24 (83%) procedures, the PBF needle yielded sufficient material for interpretation (sample adequacy). In 17/24 (71%), a correct diagnosis was made with the material from the PBF needle (diagnostic accuracy). All participating endoscopists experienced a learning curve. (Per)procedural technical issues occurred in four cases (17%), but there were no adverse events. The PBF needle is a safe and potentially useful device to obtain an EUS-guided biopsy specimen. As the design of the PBF needle is different to core biopsy FNB needles, specific training will likely further improve the performance of the PBF needle. Furthermore, the design of the needle needs further improvement to make it more robust in clinical practice.