Preliminary results using a kit to measure tamoxifen and metabolites concentrations in capillary blood samples from women with breast cancer.
Ontology highlight
ABSTRACT: The aim of the study was to compare 3 blood sampling methods, including capillary blood sampling, for determining Tamoxifen (TAM), Z-endoxifen (END), and 4-hydroxytamoxifen (4HT) concentrations. High performance liquid chromatography-mass spectrometry was used to quantify concentrations of TAM, END, and 4HT in plasma, venous blood, and capillary blood samples of 16 participants on TAM therapy for breast cancer. The rhelise kit was used for capillary sampling. Calibration curves using 13C-labeled analogs of TAM, END, and 4HT as internal standards were used for quantifications. A capillary sampling kit was used successfully for all participants. Mean TAM concentrations did not differ significantly in the 3 types of samples. Mean END and 4HT concentrations did differ significantly
SUBMITTER: Rehnmark S
PROVIDER: S-EPMC8803831 | biostudies-literature | 2022 Jan
REPOSITORIES: biostudies-literature
ACCESS DATA