Robust and bias-free localization of individual fixed dipole emitters achieving the Cramer Rao bound for applications in cryo-single molecule localization microscopy.


ABSTRACT: Single molecule localization microscopy (SMLM) has the potential to resolve structural details of biological samples at the nanometer length scale. Compared to room temperature experiments, SMLM performed under cryogenic temperature achieves higher photon yields and, hence, higher localization precision. However, to fully exploit the resolution it is crucial to account for the anisotropic emission characteristics of fluorescence dipole emitters with fixed orientation. In case of slight residual defocus, localization estimates may well be biased by tens of nanometers. We show here that astigmatic imaging in combination with information about the dipole orientation allows to extract the position of the dipole emitters without localization bias and down to a precision of 1 nm, thereby reaching the corresponding Cramér Rao bound. The approach is showcased with simulated data for various dipole orientations, and parameter settings realistic for real life experiments.

SUBMITTER: Hinterer F 

PROVIDER: S-EPMC8815875 | biostudies-literature | 2022

REPOSITORIES: biostudies-literature

altmetric image

Publications

Robust and bias-free localization of individual fixed dipole emitters achieving the Cramér Rao bound for applications in cryo-single molecule localization microscopy.

Hinterer Fabian F   Schneider Magdalena C MC   Hubmer Simon S   López-Martinez Montserrat M   Zelger Philipp P   Jesacher Alexander A   Ramlau Ronny R   Schütz Gerhard J GJ  

PloS one 20220204 2


Single molecule localization microscopy (SMLM) has the potential to resolve structural details of biological samples at the nanometer length scale. Compared to room temperature experiments, SMLM performed under cryogenic temperature achieves higher photon yields and, hence, higher localization precision. However, to fully exploit the resolution it is crucial to account for the anisotropic emission characteristics of fluorescence dipole emitters with fixed orientation. In case of slight residual  ...[more]

Similar Datasets

| S-EPMC9050814 | biostudies-literature
| S-EPMC11846865 | biostudies-literature
| S-EPMC6447464 | biostudies-literature
| S-EPMC5843523 | biostudies-literature
| S-EPMC5191044 | biostudies-other
| S-EPMC8822470 | biostudies-literature
| S-EPMC5879467 | biostudies-literature
| S-EPMC9419619 | biostudies-literature
| S-EPMC5735365 | biostudies-literature
| S-EPMC8831523 | biostudies-literature