Redundancy cancellation of compressed measurements by QRS complex alignment.


ABSTRACT: The demand for long-term continuous care has led healthcare experts to focus on development challenges. On-chip energy consumption as a key challenge can be addressed by data reduction techniques. In this paper, the pseudo periodic nature of ElectroCardioGram(ECG) signals has been used to completely remove redundancy from frames. Compressing aligned QRS complexes by Compressed Sensing (CS), result in highly redundant measurement vectors. By removing this redundancy, a high cluster of near zero samples is gained. The efficiency of the proposed algorithm is assessed using the standard MIT-BIH database. The results indicate that by aligning ECG frames, the proposed technique can achieve superior reconstruction quality compared to state-of-the-art techniques for all compression ratios. This st

SUBMITTER: Nasimi F 

PROVIDER: S-EPMC8824321 | biostudies-literature | 2022

REPOSITORIES: biostudies-literature