Comparing clinical performance of current implantable cardioverter-defibrillator implantation recommendations in arrhythmogenic right ventricular cardiomyopathy.


ABSTRACT:

Aims

Arrhythmogenic right ventricular cardiomyopathy (ARVC) patients have an increased risk of ventricular arrhythmias (VA). Four implantable cardioverter-defibrillator (ICD) recommendation algorithms are available The International Task Force Consensus ('ITFC'), an ITFC modification by Orgeron et al. ('mITFC'), the AHA/HRS/ACC guideline for VA management ('AHA'), and the HRS expert consensus statement ('HRS'). This study aims to validate and compare the performance of these algorithms in ARVC.

Methods and results

We classified 617 definite ARVC patients (38.5 ± 15.1 years, 52.4% male, 39.2% prior sustained VA) according to four algorithms. Clinical performance was evaluated by sensitivity, specificity, ROC-analysis, and decision curve analysis for any sustained VA and for fast VA (>250 b.p.m.). During 6.4 [2.8-11.5] years follow-up, 282 (45.7%) patients experienced any sustained VA, and 63 (10.2%) fast VA. For any sustained VA, ITFC and mITFC provide higher sensitivity than AHA and HRS (94.0-97.8% vs. 76.7-83.5%), but lower specificity (15.9-32.0% vs. 42.7%-60.1%). Similarly, for fast VA, ITFC and mITFC provide higher sensitivity than AHA and HRS (95.2-97.1% vs. 76.7-78.4%) but lower specificity (42.7-43.1 vs. 76.7-78.4%). Decision curve analysis showed ITFC and mITFC to be superior for a 5-year sustained VA risk ICD indication threshold between 5-25% or 2-9% for fast VA.

Conclusion

The ITFC and mITFC provide the highest protection rates, whereas AHA and HRS decrease unnecessary ICD placements. ITFC or mITFC should be used if we consider the 5-year threshold for ICD indication to lie within 5-25% for sustained VA or 2-9% for fast VA. These data will inform decision-making for ICD placement in ARVC.

SUBMITTER: Bosman LP 

PROVIDER: S-EPMC8824519 | biostudies-literature | 2022 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparing clinical performance of current implantable cardioverter-defibrillator implantation recommendations in arrhythmogenic right ventricular cardiomyopathy.

Bosman Laurens P LP   Bosman Laurens P LP   Nielsen Gerlach Claire L CL   Cadrin-Tourigny Julia J   Orgeron Gabriela G   Tichnell Crystal C   Murray Brittney B   Bourfiss Mimount M   van der Heijden Jeroen F JF   Yap Sing-Chien SC   Zeppenfeld Katja K   van den Berg Maarten P MP   Wilde Arthur A M AAM   Asselbergs Folkert W FW   Tandri Hariskrishna H   Calkins Hugh H   van Tintelen J Peter JP   James Cynthia A CA   Te Riele Anneline S J M ASJM  

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 20220201 2


<h4>Aims</h4>Arrhythmogenic right ventricular cardiomyopathy (ARVC) patients have an increased risk of ventricular arrhythmias (VA). Four implantable cardioverter-defibrillator (ICD) recommendation algorithms are available The International Task Force Consensus ('ITFC'), an ITFC modification by Orgeron et al. ('mITFC'), the AHA/HRS/ACC guideline for VA management ('AHA'), and the HRS expert consensus statement ('HRS'). This study aims to validate and compare the performance of these algorithms i  ...[more]

Similar Datasets

| S-EPMC6404172 | biostudies-literature
| S-EPMC5669204 | biostudies-literature
| S-EPMC9843673 | biostudies-literature
| S-EPMC10202497 | biostudies-literature
| S-EPMC7726970 | biostudies-literature
| S-EPMC6738937 | biostudies-literature
| S-EPMC6709696 | biostudies-literature
| S-EPMC4802466 | biostudies-other