ABSTRACT: Introduction
During prostate radiotherapy treatment, it is important to ensure the position of the bladder and prostate is consistent between treatments. The aim of this study was to provide a quantitative basis for incorporating ultrasound bladder volume estimates into local practice for prostate radiotherapy.Methods
Agreement between bladder volume estimates obtained using computed tomography (CT) and ultrasound was assessed. Analysis of bladder volumes between planning and treatment scans was used to quantify expected variations in bladder volume over the course of radiotherapy. Dose-volume statistics were estimated and compared to planned dose constraints to propose a target bladder volume and tolerance.Results
Bladder volume measurements were obtained from 19 r
SUBMITTER: Smith L
PROVIDER: S-EPMC8841937 | biostudies-literature | 2022 Feb