Unknown

Dataset Information

0

Electrocochleography and cognition are important predictors of speech perception outcomes in noise for cochlear implant recipients.


ABSTRACT: Although significant progress has been made in understanding outcomes following cochlear implantation, predicting performance remains a challenge. Duration of hearing loss, age at implantation, and electrode positioning within the cochlea together explain ~ 25% of the variability in speech-perception scores in quiet using the cochlear implant (CI). Electrocochleography (ECochG) responses, prior to implantation, account for 47% of the variance in the same speech-perception measures. No study to date has explored CI performance in noise, a more realistic measure of natural listening. This study aimed to (1) validate ECochG total response (ECochG-TR) as a predictor of performance in quiet and (2) evaluate whether ECochG-TR explained variability in noise performance. Thirty-five adult CI recipients were enrolled with outcomes assessed at 3-months post-implantation. The results confirm previous studies showing a strong correlation of ECochG-TR with speech-perception in quiet (r = 0.77). ECochG-TR independently explained 34% of the variability in noise performance. Multivariate modeling using ECochG-TR and Montreal Cognitive Assessment (MoCA) scores explained 60% of the variability in speech-perception in noise. Thus, ECochG-TR, a measure of the cochlear substrate prior to implantation, is necessary but not sufficient for explaining performance in noise. Rather, a cognitive measure is also needed to improve prediction of noise performance.

SUBMITTER: Walia A 

PROVIDER: S-EPMC8866505 | biostudies-literature | 2022 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Electrocochleography and cognition are important predictors of speech perception outcomes in noise for cochlear implant recipients.

Walia Amit A   Shew Matthew A MA   Kallogjeri Dorina D   Wick Cameron C CC   Durakovic Nedim N   Lefler Shannon M SM   Ortmann Amanda J AJ   Herzog Jacques A JA   Buchman Craig A CA  

Scientific reports 20220223 1


Although significant progress has been made in understanding outcomes following cochlear implantation, predicting performance remains a challenge. Duration of hearing loss, age at implantation, and electrode positioning within the cochlea together explain ~ 25% of the variability in speech-perception scores in quiet using the cochlear implant (CI). Electrocochleography (ECochG) responses, prior to implantation, account for 47% of the variance in the same speech-perception measures. No study to d  ...[more]

Similar Datasets

| S-EPMC8880977 | biostudies-literature
| S-EPMC4430230 | biostudies-literature
| S-EPMC9443016 | biostudies-literature
| S-EPMC8270138 | biostudies-literature
| S-EPMC8503862 | biostudies-literature
| S-EPMC8407755 | biostudies-literature
| S-EPMC8296973 | biostudies-literature
| S-EPMC10338449 | biostudies-literature
| S-EPMC8221708 | biostudies-literature
| S-EPMC4617902 | biostudies-literature