Unknown

Dataset Information

0

The data of an all-solid-state acupuncture needle based potentiometric microelectrode for in vivo monitoring of calcium ions in rat cerebrospinal fluid.


ABSTRACT: These data contain the details of the fabrication of the calcium ion-selective microelectrode (Ca2+-ISμEs) modified with poly(3,4-ethylenedioxythiophene)-poly(sodium 4-styrenesulfonate) (PEDOT(PSS)) as solid contact. The electrochemical impedance spectroscopy was carried out for the investigation of the resistance of the Ca2+-ISμEs. The thickness of the solid contact and the calcium ion-selective membrane was investigated by SEM. Potential-time curve of the electrodeposition of the PEDOT/PSS film onto the surface of the microelectrodes under the applied current of 0.5 μA for 200 s was recorded. The proposed Ca2+-ISμE was optimized through conditioning in different CaCl2 solutions ranged from 1.0 × 10-6 to 3.1 × 10-3 M for different time before use. The anti-fouling property of the Ca2+-ISμEs against proteins was investigated through taking BSA as the model protein. The developed Ca2+-ISμEs were used for the in vivo monitoring of the calcium ions in rat cerebrospinal fluid under the stimuli of the spinal cord transection in a living animal.

SUBMITTER: Zhai J 

PROVIDER: S-EPMC8866674 | biostudies-literature | 2022 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

The data of an all-solid-state acupuncture needle based potentiometric microelectrode for <i>in vivo</i> monitoring of calcium ions in rat cerebrospinal fluid.

Zhai Jiali J   Zhang Yaqun Y   Zhao Dongmei D   Kou Lijuan L   Zhao Guangtao G  

Data in brief 20220215


These data contain the details of the fabrication of the calcium ion-selective microelectrode (Ca<sup>2+</sup>-ISμEs) modified with poly(3,4-ethylenedioxythiophene)-poly(sodium 4-styrenesulfonate) (PEDOT(PSS)) as solid contact. The electrochemical impedance spectroscopy was carried out for the investigation of the resistance of the Ca<sup>2+</sup>-ISμEs. The thickness of the solid contact and the calcium ion-selective membrane was investigated by SEM. Potential-time curve of the electrodepositio  ...[more]

Similar Datasets

| S-EPMC4873256 | biostudies-literature
| S-EPMC9832439 | biostudies-literature
| PRJNA856347 | ENA
| S-EPMC8251608 | biostudies-literature
| S-EPMC11835020 | biostudies-literature
| S-EPMC8650691 | biostudies-literature
| S-EPMC10098084 | biostudies-literature
| S-EPMC7847245 | biostudies-literature
| S-EPMC5762724 | biostudies-literature
| S-EPMC11651633 | biostudies-literature