Unknown

Dataset Information

Assessing patent ductus arteriosus in preterm infants from standard neonatal intensive care monitoring.


ABSTRACT: Monitoring patent ductus arteriosus (PDA) in premature infants is currently performed intermittently using echocardiography which requires considerable expertise. The aim of this pilot study was to investigate whether PDA status could be assessed from standard neonatal intensive care monitoring. Electrocardiography (ECG) and blood pressure (BP) waveforms were acquired from extremely preterm infants using standard neonatal monitors. We developed software using MATLAB to analyse ECG and BP waveforms and their interrelationships in terms of pulse transit time (PTT) and pulse wave velocity (PWV). The times from peak systolic BP to diastolic trough (BPFt) and from the diastolic trough to peak systolic BP (BPRt) were also calculated. PTT, BPFt and BPRt were normalised for heart rate (HR) termed

SUBMITTER: Kotidis C 

PROVIDER: S-EPMC8897357 | biostudies-literature | 2022 Mar

REPOSITORIES: biostudies-literature