Local Exhaust Ventilation to Control Dental Aerosols and Droplets.
Ontology highlight
ABSTRACT: Dental procedures produce aerosols that may remain suspended and travel significant distances from the source. Dental aerosols and droplets contain oral microbes, and there is potential for infectious disease transmission and major disruption to dental services during infectious disease outbreaks. One method to control hazardous aerosols often used in industry is local exhaust ventilation (LEV). The aim of this study was to investigate the effect of LEV on aerosols and droplets produced during dental procedures. Experiments were conducted on dental mannequins in an 825.4-m3 open-plan clinic and a 49.3-m3 single surgery. Ten-minute crown preparations were performed with an air-turbine handpiece in the open-plan clinic and 10-min full-mouth ultrasonic scaling in the sin
SUBMITTER: Allison JR
PROVIDER: S-EPMC8935467 | biostudies-literature | 2022 Apr
REPOSITORIES: biostudies-literature
ACCESS DATA