Evaluation of multiplex assay platforms for detection of influenza hemagglutinin subtype specific antibody responses.


ABSTRACT: Influenza hemagglutination inhibition (HI) and virus microneutralization assays (MN) are widely used for seroprevalence studies. However, these assays have limited field portability and are difficult to fully automate for high throughput laboratory testing. To address these issues, three multiplex influenza subtype-specific antibody detection assays were developed using recombinant hemagglutinin antigens in combination with Chembio, Luminex®, and ForteBio® platforms. Assay sensitivity, specificity, and subtype cross-reactivity were evaluated using a panel of well characterized human sera. Compared to the traditional HI, assay sensitivity ranged from 87% to 92% and assay specificity in sera collected from unexposed persons ranged from 65% to 100% across the platforms. High assay specificity (86-100%) for A(H5N1) rHA was achieved for sera from exposed or unexposed to hetorosubtype influenza HAs. In contrast, assay specificity for A(H1N1)pdm09 rHA using sera collected from A/Vietnam/1204/2004 (H5N1) vaccinees in 2008 was low (22-30%) in all platforms. Although cross-reactivity against rHA subtype proteins was observed in each assay platform, the correct subtype specific responses were identified 78%-94% of the time when paired samples were available for analysis. These results show that high throughput and portable multiplex assays that incorporate rHA can be used to identify influenza subtype specific infections.

SUBMITTER: Li ZN 

PROVIDER: S-EPMC8958803 | biostudies-literature | 2017 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of multiplex assay platforms for detection of influenza hemagglutinin subtype specific antibody responses.

Li Zhu-Nan ZN   Weber Kimberly M KM   Limmer Rebecca A RA   Horne Bobbi J BJ   Stevens James J   Schwerzmann Joy J   Wrammert Jens J   McCausland Megan M   Phipps Andrew J AJ   Hancock Kathy K   Jernigan Daniel B DB   Levine Min M   Katz Jacqueline M JM   Miller Joseph D JD  

Journal of virological methods 20170117


Influenza hemagglutination inhibition (HI) and virus microneutralization assays (MN) are widely used for seroprevalence studies. However, these assays have limited field portability and are difficult to fully automate for high throughput laboratory testing. To address these issues, three multiplex influenza subtype-specific antibody detection assays were developed using recombinant hemagglutinin antigens in combination with Chembio, Luminex<sup>®</sup>, and ForteBio<sup>®</sup> platforms. Assay  ...[more]

Similar Datasets

| S-EPMC5410722 | biostudies-literature
| S-EPMC7858056 | biostudies-literature
| S-EPMC8592197 | biostudies-literature
| S-EPMC7455636 | biostudies-literature
| S-EPMC7695067 | biostudies-literature
| S-EPMC6736996 | biostudies-literature
| S-EPMC10801708 | biostudies-literature
| S-EPMC7391517 | biostudies-literature
| S-EPMC4188494 | biostudies-literature
| S-EPMC7790091 | biostudies-literature