A Smart System for the Contactless Measurement of Energy Expenditure.


ABSTRACT: Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO2 production, VCO2 (mL/min), and/or O2 consumption, VO2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO2 from a room's ambient CO2 concentration transients was evaluated. Resting EE (REE) and exercise VCO2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration's influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14-19 min of REE measurement and for 4.8-7.0 min of exercise, using known room's air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE's measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects' VCO2 and λ for CO2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).

SUBMITTER: Sprowls M 

PROVIDER: S-EPMC8963031 | biostudies-literature | 2022 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Smart System for the Contactless Measurement of Energy Expenditure.

Sprowls Mark M   Victor Shaun S   Mora Sabrina Jimena SJ   Osorio Oscar O   Pyznar Gabriel G   Destaillats Hugo H   Wheatley-Guy Courtney C   Johnson Bruce B   Kulick Doina D   Forzani Erica E  

Sensors (Basel, Switzerland) 20220210 4


Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO<sub>2</sub> production, VCO<sub>2</sub> (mL/min), and/or O<sub>2</sub> consumption, VO<sub>2</sub> (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO<sub>2</sub> from a room's ambient CO<sub>2</sub> concentration transients was evaluated. Resting EE (REE) and exercise VCO<sub>2</sub> measurements  ...[more]

Similar Datasets

| S-EPMC10875158 | biostudies-literature
| S-EPMC6584582 | biostudies-literature
2023-04-20 | GSE230208 | GEO
| PRJNA957834 | ENA
| S-EPMC9801248 | biostudies-literature
| S-EPMC5332318 | biostudies-literature
| S-EPMC9966313 | biostudies-literature
| S-EPMC9909604 | biostudies-literature
| S-EPMC6392078 | biostudies-literature
| S-EPMC8279134 | biostudies-literature