Comparison of a Short Versus Long Stokes Shift Near-Infrared Dye During Intraoperative Molecular Imaging.


ABSTRACT:

Purpose

Intraoperative molecular imaging (IMI) utilizes optical dyes that accumulate within tumors to assist with detection during a cancer operation. IMI can detect disease not visualized preoperatively, as well as positive margins. However, these dyes are limited by autofluorescence, signal reflection, and photon-scatter. We hypothesize that a novel dye with a wide separation between excitation and emission spectra, SS180, would help overcome these obstacles.

Procedures

Two targeted molecular contrast agents, OTL38 and SS180, were selected for this study. Both dyes had the same targeting ligand to folate receptor alpha (FRα). OTL38, a well-annotated IMI agent in human trials, has a Stokes shift of 22 nm, whereas SS180, the new dye, has a Stokes shift of 129 nm. Cell lines