Unknown

Dataset Information

Optical Coherence Tomography to Assess Proximal Side Optimization Technique in Crush Stenting.


ABSTRACT:

Aim

The aim of this study was to explore the potential intraprocedural benefits of the Proximal Side Optimization (PSO) technique by Optical Coherence Tomography (OCT).

Methods

A case series of 10 consecutive true bifurcation lesions, with severe long pathology of long side branch (SB), were randomly assigned to be treated by standard DK Crush procedure (non-PSO group) as compared to DK Crush in PSO modification (PSO group). The data from OCT investigation before crushing of the SB Drug-Eluting Stent (DES), after crushing, after first kissing balloon inflation (KBI), and after final angiography were compared between the two groups (Public trials registry ISRCTN23355755).

Results

All 10 cases were successfully treated by the assigned technique. The two groups were simi

SUBMITTER: Lavarra F 

PROVIDER: S-EPMC8965003 | biostudies-literature | 2022

REPOSITORIES: biostudies-literature