In Situ Pulmonary Thrombolysis and Perfusion Lung Angiography in Severe COVID-19 Respiratory Failure.


ABSTRACT: A proof-of-concept study using thrombolysis with catheter-directed tissue plasminogen activator (tPA) and pulmonary angiography imaging was performed to visualize perfusion deficits and reperfusion/therapeutic effects of tPA.

Design

A prospective, open-label, compassionate study. Descriptive statistics were presented for categorical variables and as means with sds for continuous variables. The Wilcoxon test was used to determine the differences between the two-related samples and a t test for continuous variables. Statistical significance was set at p value of less than 0.05. Agreement between observations was evaluated using the Kappa Cohen index and overall agreement using the Fleiss Kappa coefficient.

Setting

A single COVID-19 ICU of Mexico´s General Hospital Dr Eduardo Liceaga.

Subjects

Fifteen patients with severe Delta variant severe acute respiratory syndrome coronavirus 2 infection, 18-75 years old, requiring mechanical ventilation with a persistent Fio2 requirement of 70% or higher and Pao2/Fio2 ratio (or imputed ratio) less than 150 for more than 4 hours. The coagulation inclusion criteria were International Society on Thrombosis and Haemostasis score greater than 5, and presence of a d-dimer greater than 1,200, with viscoelastic testing using rotational thromboelastometry (Instrumentation Laboratories, Mexico City, Mexico) showing both hypercoagulability (EXTEM amplitude at 5 min > 65 FIBTEM > 30) and hypofibrinolysis (EXTEM maximum lysis < 8%).

Interventions

Catheter-directed tPA angiography and iFlow system analysis to assess pre-tPA baseline pulmonary perfusion and changes in response to thrombolysis.

Results

Nine patients had microvascular filling defects demonstrated by angiography, and good agreement was found with iFlow analysis (ƙ = 0.714). Statistically significant differences were identified in the area under the curve (AUC) region of interest/AUC reference tissue with and without filling defects in phase 2 DM -0.09206 (sd ± 0.16684) (p = 0.003). The Pao2/Fio2 values measured immediately and 48 hours after the procedure were significantly higher (p = 0.001 and p = 0.005, respectively). Statistically significant differences were found in d-dimer values (p = 0.007), Fio2 (p = 0.002), and oxygen saturation in arterial blood/Fio2 (p = 0.045), as well as in the number of patients who required prone positioning before, immediately after the procedure, and at 48 hours after the procedure (p = 0.002).

Conclusions

Thrombolysis with catheter-directed tPA resulted in imaging evidence via pulmonary angiography and iFlow technology of improved lung perfusion in COVID-19 patients with severe respiratory failure.

SUBMITTER: Perez-Calatayud AA 

PROVIDER: S-EPMC8966962 | biostudies-literature | 2022 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications


A proof-of-concept study using thrombolysis with catheter-directed tissue plasminogen activator (tPA) and pulmonary angiography imaging was performed to visualize perfusion deficits and reperfusion/therapeutic effects of tPA.<h4>Design</h4>A prospective, open-label, compassionate study. Descriptive statistics were presented for categorical variables and as means with sds for continuous variables. The Wilcoxon test was used to determine the differences between the two-related samples and a <i>t</  ...[more]

Similar Datasets

| S-EPMC8446949 | biostudies-literature
| S-EPMC7392155 | biostudies-literature
| S-EPMC7365368 | biostudies-literature
| S-EPMC9353318 | biostudies-literature
| S-EPMC8149172 | biostudies-literature
| S-EPMC7315890 | biostudies-literature
| S-EPMC9190053 | biostudies-literature
| S-EPMC7668008 | biostudies-literature
| S-EPMC3402091 | biostudies-literature
| S-EPMC9038965 | biostudies-literature