Unknown

Dataset Information

Comparison of Efficacy and Safety Between Standard, Accelerated Epithelium-Off and Transepithelial Corneal Collagen Crosslinking in Pediatric Keratoconus: A Meta-Analysis.


ABSTRACT:

Purpose

The purpose of the study is to compare the efficacy of standard epithelium-off CXL (SCXL), accelerated epithelium-off CXL (ACXL), and transepithelial crosslinking CXL (TECXL) for pediatric keratoconus.

Methods

A literature search on the efficacy of SCXL, ACXL, and TECXL [including accelerated TECXL (A-TECXL)] for keratoconus patients younger than 18 years was conducted using PubMed, Cochrane Library, ClinicalTrials.gov, and EMBASE up to 2021. Primary outcomes were changes in uncorrected visual acuity (UCVA) and maximum keratometry (Kmax) after CXL. Secondary outcomes were changes in best-corrected visual acuity (BCVA), mean refractive spherical equivalent (MRSE), and central corneal thickness (CCT). Estimations were analyzed by weighted mean difference (WMD) and 95%

SUBMITTER: Li Y 

PROVIDER: S-EPMC8968048 | biostudies-literature | 2022