The utilization of atrial sensing dipole in single lead implantable cardioverter defibrillator for detection of new-onset atrial high-rate episodes or subclinical atrial fibrillation: A systematic review and meta-analysis.


ABSTRACT: This meta-analysis aims to evaluate the performance of atrial sensing dipole in single lead implantable cardioverter defibrillator (VDD-ICD) recipients in particular diagnosing new-onset atrial high-rate episodes (AHREs) defined as rate threshold of 200 beats per minute, or subclinical atrial fibrillation (SCAF) defined as device-detected AF without symptoms. We comprehensively searched PubMed, Embase, and ClinicalTrials.gov. Studies comparing contemporary single- and dual-chamber ICD (VVI-/DDD-ICD) versus VDD-ICD were included. Restricted maximum likelihood method for random effect model and Mantel-Haenszel method for fixed effect model were used to estimate the effect size of new-onset AHREs, or SCAF detection in each group. Three prospective studies were identified and total of 991 participants were included. There were 330 (33.3%) in VDD-ICD and 661 (66.7%) in VVI-/DDD-ICD. Most (78%) participants were men. Median follow-up was from 365 days to 847 days. VDD-ICD has a higher likelihood of detecting AHREs or SCAF as compared to VVI-/DDD-ICD [(OR random effect : 2.6; 95% CI: 1.2, 5.8; p = .018); I-squared = 67.8%, = .019]. This difference was more apparently seen in the comparison between VDD-ICD and VVI-ICD [(OR random effect: 3.8; 95% CI: 2.1, 6.6, p < .001), I-squared = 0.0%, = .518]. The result is same as fixed effect. Rate of AHREs detection observed in VDD-ICD was not statistically different when compared to the only group with DDD-ICD from SENSE trial. In conclusion, this meta-analysis reveals that the use of floating atrial sensing dipole in VDD-ICD increases the detection of new-onset AHREs or SCAF when compared to VVI-ICD, with similar atrial sensing performance to DDD-ICD.

SUBMITTER: Pung X 

PROVIDER: S-EPMC8977580 | biostudies-literature | 2022 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

The utilization of atrial sensing dipole in single lead implantable cardioverter defibrillator for detection of new-onset atrial high-rate episodes or subclinical atrial fibrillation: A systematic review and meta-analysis.

Pung Xuanming X   Hong Daniel Zhihao DZ   Ho Tzyy Yeou TY   Shen Xiayan X   Tan Pei Ting PT   Yeo Colin C   Tan Vern Hsen VH  

Journal of arrhythmia 20220115 2


This meta-analysis aims to evaluate the performance of atrial sensing dipole in single lead implantable cardioverter defibrillator (VDD-ICD) recipients in particular diagnosing new-onset atrial high-rate episodes (AHREs) defined as rate threshold of 200 beats per minute, or subclinical atrial fibrillation (SCAF) defined as device-detected AF without symptoms. We comprehensively searched PubMed, Embase, and ClinicalTrials.gov. Studies comparing contemporary single- and dual-chamber ICD (VVI-/DDD-  ...[more]

Similar Datasets

| S-EPMC6852241 | biostudies-literature
| S-EPMC10227664 | biostudies-literature
| S-EPMC4055293 | biostudies-literature
| S-EPMC7360169 | biostudies-literature
| S-EPMC7132187 | biostudies-literature
| S-EPMC5419807 | biostudies-literature
| S-EPMC10492968 | biostudies-literature
| S-EPMC7299732 | biostudies-literature
| S-EPMC4845221 | biostudies-literature
| S-EPMC2904834 | biostudies-literature