Magnetic nanoprobes for rapid detection of copper ion in aqueous environment by surface-enhanced Raman spectroscopy.
Ontology highlight
ABSTRACT: Excessive copper ions in drinking water could cause serious health issues, such as gastrointestinal disorders and cirrhosis, and they are associated with Alzheimer's disease. ICP-OES, ICP-MS, and AAS are the most common methods of copper ion determination. However, the high cost of sample preparation and labor limit the possibility of on-site detection. In this study, rapid monitoring of copper ion through the SERS technique was evaluated. Fe3O4@SiO2-Ag-4MBA nanoparticles were investigated as SERS-activated magnetic nanoprobes. These magnetic nanoprobes underwent superparamagnetism for rapid aggregation in seconds and provided selectivity in sensing copper ions. According to the dose-response curve of the SERS spectra, the limit of detection (LOD) was 0.421
SUBMITTER: Hsieh MY
PROVIDER: S-EPMC8978930 | biostudies-literature | 2021 Dec
REPOSITORIES: biostudies-literature
ACCESS DATA