Unknown

Dataset Information

State-of-the-art silicone molded models for simulation of arterial switch operation: Innovation with parting-and-assembly strategy.


ABSTRACT:

Background

Three-dimensional (3D) printed models are widely accepted for use in training of various surgical procedures for congenital heart disease; however, their physical properties have been considered suboptimum for procedures. We created silicone molded models produced using a novel "parting and assembly" strategy and compared their suitability for hands-on training with that of conventional 3D printed models.

Methods

Computed tomography imaging data from 2 patients with transposition of the great arteries were used. The heart was divided into multiple parts (atria, ventricles, great arteries, coronary arteries, and valves), and molds of each part were created. The parts reproduced by silicone molding were assembled using an adhesive agent. In an online course, 2 silic

SUBMITTER: Peel B 

PROVIDER: S-EPMC8987302 | biostudies-literature | 2022 Apr

REPOSITORIES: biostudies-literature