Unknown

Dataset Information

0

Relationship between TIA minus C0-7 angle and C2-7 SVA: analysis of 113 symptomatic patients.


ABSTRACT:

Background

Measurement of T1 slope (T1S) can be difficult due to the anatomical positioning of the shoulders. And thoracic inlet angle (TIA) was a morphological parameter and not changed by the position. We proposed a new parameter, TIA minus C0-7 angle (TIA-C07), to evaluate C2-7 SVA in order to overcome the T1S imperfection.

Methods

This was a retrospective radiological analysis of symptomatic subjects. The following cervical parameters were measured: Cervical lordosis angle (CL), C0-7 angle (C0-7), occiput-C2 lordosis angle (O-C2), C2-7 sagittal vertical axis (C2-7 SVA), TIA and TIA-C07. The Pearson correlation test was calculated, and the stepwise multiple regression analysis was conducted to determine the best predictor for C2-7 SVA. A paired sample t test was used to compare the predicted and measured C2-7 SVA.

Results

The mean age of 113 patients was 60.02 ± 9.67. The average O-C2, CL, C0-7, TIA, TIA-C07 and C2-C7 SVA was 29.24 ± 8.48°, 13.67 ± 11.22°, 42.91 ± 11.44°, 76.07 ± 9.54°, 33.16 ± 13.18° and 21.34 ± 11.42 mm. The predictive formula was founded: C2-7 SVA = 2.80 + 0.56 * (TIA-C07) (R = 0.645, R2 = 0.416). There was no statistical difference between the predicted and the measured C2-7 SVA (t = 0.085, P = 0.933).

Conclusions

TIA and C0-7 mismatch may significantly impact cervical alignment, and a greater T1A-C07 was related to a greater degree of C2-7 SVA. TIA-C07 may be a more important predictor for C2-7 SVA.

SUBMITTER: Yang K 

PROVIDER: S-EPMC8991799 | biostudies-literature | 2022 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Relationship between TIA minus C0-7 angle and C2-7 SVA: analysis of 113 symptomatic patients.

Yang Kai K   Li Xiang-Yu XY   Wang Yu Y   Kong Chao C   Lu Shi-Bao SB  

BMC musculoskeletal disorders 20220408 1


<h4>Background</h4>Measurement of T1 slope (T1S) can be difficult due to the anatomical positioning of the shoulders. And thoracic inlet angle (TIA) was a morphological parameter and not changed by the position. We proposed a new parameter, TIA minus C0-7 angle (TIA-C07), to evaluate C2-7 SVA in order to overcome the T1S imperfection.<h4>Methods</h4>This was a retrospective radiological analysis of symptomatic subjects. The following cervical parameters were measured: Cervical lordosis angle (CL  ...[more]

Similar Datasets

2022-08-08 | GSE206627 | GEO
2019-09-26 | PXD015391 | Pride
| PRJNA1203738 | ENA
| S-EPMC11696458 | biostudies-literature