Unknown

Dataset Information

0

Dissipation Behavior and Acute Dietary Risk Assessment of Thiamethoxam and Its Metabolite Clothianidin on Spinach.


ABSTRACT: Thiamethoxam and its metabolite clothianidin residues pose a potential threat to human health. This study aims to investigate the residue behavior and acute dietary risk assessment of thiamethoxam and clothianidin on spinach. Thiamethoxam and clothianidin were extracted using a quick, easy, cheap, effective, rugged, safe (QuEChERS) method and analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). At spike levels from 0.01 to 5 mg kg-1, the average recoveries of both analytes were in the range of 94.5-105.5%, with relative standard deviations (RSDs) of 3.8-10.9%. The dissipation behavior of thiamethoxam followed first-order kinetics, with half-lives of ≤1.6 days. Clothianidin appeared readily as a plant metabolite with highest level exhibited during 3 to 5 days after application. Temperature and light may be two main factors for degradation of thiamethoxam. Besides, acute risk assessment of thiamethoxam and clothianidin was evaluated with risk quotients (RQs) <100%, which suggested a low health risk for all consumer groups of Chinese residents.

SUBMITTER: Yang Y 

PROVIDER: S-EPMC9000691 | biostudies-literature | 2022 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dissipation Behavior and Acute Dietary Risk Assessment of Thiamethoxam and Its Metabolite Clothianidin on Spinach.

Yang Yanmei Y   Qin Shu S   Wang Xia X   Cao Junli J   Li Jindong J  

Molecules (Basel, Switzerland) 20220329 7


Thiamethoxam and its metabolite clothianidin residues pose a potential threat to human health. This study aims to investigate the residue behavior and acute dietary risk assessment of thiamethoxam and clothianidin on spinach. Thiamethoxam and clothianidin were extracted using a quick, easy, cheap, effective, rugged, safe (QuEChERS) method and analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). At spike levels from 0.01 to 5 mg kg−1, the average recoveries of both analytes w  ...[more]

Similar Datasets

| S-EPMC10527991 | biostudies-literature
| S-EPMC11475861 | biostudies-literature
| S-EPMC9738132 | biostudies-literature
| S-EPMC8122877 | biostudies-literature
| S-EPMC10672735 | biostudies-literature
| S-EPMC9457792 | biostudies-literature
| S-EPMC10048305 | biostudies-literature
| S-EPMC9325977 | biostudies-literature
| S-EPMC9626860 | biostudies-literature
| S-EPMC6299462 | biostudies-literature