Unknown

Dataset Information

Intercomparison of PurpleAir Sensor Performance over Three Years Indoors and Outdoors at a Home: Bias, Precision, and Limit of Detection Using an Improved Algorithm for Calculating PM2.5.


ABSTRACT: Low-cost particle sensors are now used worldwide to monitor outdoor air quality. However, they have only been in wide use for a few years. Are they reliable? Does their performance deteriorate over time? Are the algorithms for calculating PM2.5 concentrations provided by the sensor manufacturers accurate? We investigate these questions using continuous measurements of four PurpleAir monitors (8 sensors) under normal conditions inside and outside a home for 1.5-3 years. A recently developed algorithm (called ALT-CF3) is compared to the two existing algorithms (CF1 and CF_ATM) provided by the Plantower manufacturer of the PMS 5003 sensors used in PurpleAir PA-II monitors. Results. The Plantower CF1 algorithm lost 25-50% of all indoor data due in part to the practice of assigning zero to all

SUBMITTER: Wallace L 

PROVIDER: S-EPMC9002513 | biostudies-literature | 2022 Apr

REPOSITORIES: biostudies-literature