Ideal Combinations of Acceleration-Based Intensity Metrics and Sensor Positions to Monitor Exercise Intensity under Different Types of Sports.
Ontology highlight
ABSTRACT: This study quantified the strength of the relationship between the percentage of heart rate reserve (%HRR) and two acceleration-based intensity metrics (AIMs) at three sensor-positions during three sport types (running, basketball, and badminton) under three intensity conditions (locomotion speeds). Fourteen participants (age: 24.9 ± 2.4 years) wore a chest strap HR monitor and placed three accelerometers at the left wrist (non-dominant), trunk, and right shank, respectively. The %HRR and two different AIMs (Player Load per minute [PL/min] and mean amplitude deviation [MAD]) during exercise were calculated. During running, both AIMs at the shank and PL at the wrist had strong correlations (r = 0.777-0.778) with %HRR; while other combinations were negligible to moderate (r = 0.065-0.451). F
SUBMITTER: Chen WH
PROVIDER: S-EPMC9003469 | biostudies-literature | 2022 Mar
REPOSITORIES: biostudies-literature
ACCESS DATA