Impact of baseline impedance of pulmonary vein antrum on success of catheter ablation for paroxysmal atrial fibrillation guided by ablation index.


ABSTRACT:

Objective

Ablation index (AI) is an effective ablation quality marker. Impedance is also an important factor for lesion formation. The present study evaluated the influence of the baseline impedance in the effect of ablation for atrial fibrillation (AF) guided by AI.

Methods

This was a retrospective study. 101 patients with paroxysmal AF (PAF) were enrolled. All patients underwent radiofrequency ablation guided by the same AI strategy. The ablation strategy was pulmonary vein (PV) isolation with non-PV triggers ablation. The baseline impedance of the ablation points was recorded. The patients were followed up every 3 months or so.

Results

During a median follow-up of 12 (4-14) months, freedom from AF/atrial tachycardia recurrence were 82.2%. No difference existed in b