Ontology highlight
ABSTRACT: Background
Early type IIIb endoleak is a very rare complication of endovascular aneurysm repair (EVAR).Case presentation
An 87-year-old man was diagnosed with infrarenal abdominal aortic aneurysm. The patient underwent EVAR using the Endurant stent graft. Postoperative color duplex ultrasound revealed a regular row of pulsatile blood flow from the main body and left leg. The blood flow appeared to be bleeding from the stent suture lines because of its regularity. Type IIIb endoleak was suspected due to stent suture line fabric breakage but was not treated surgically or endovascularly because of the patient's poor general health status. Six months later, contrast-enhanced CT demonstrated a deformation and enlargement of the aneurysm sac as well as an oozing of the contrast m
SUBMITTER: Takahashi S
PROVIDER: S-EPMC9018899 | biostudies-literature | 2022 Apr