Unknown

Dataset Information

Evaluation of Conformity and Homogeneity Indices Consistency Throughout the Course of Head and Neck Cancer Treatment With and Without Using Adaptive Volumetric Modulated Arc Radiation Therapy.


ABSTRACT:

Purpose

Conformity indices (CI) and homogeneity indices (HI) are important tools for evaluating treatment plan quality. In this study, we evaluate the consistency of these indices with respect to anatomic changes undergone by patients.

Methods and materials

Fifty-five patients with advanced head and neck cancer were treated with simultaneous integrated boost volumetric modulated arc therapy. The initial plan (iplan) then was projected on the new computed tomographs (CT) and 2 adaptive plans (Aplans) for each patient were performed on the new CTs. A comparison of CI and HI between the iplan, hybrid plan (Hplan), and Aplan was performed.

Results

There was a significant weight loss (P < .001) between CT1, CT2, and CT3, where the median weight at CT1 was 75.78 (68.

SUBMITTER: Al-Rawi SAI 

PROVIDER: S-EPMC9026624 | biostudies-literature | 2022 Sep-Oct

REPOSITORIES: biostudies-literature