Ontology highlight
ABSTRACT: Purpose
To compare the repair strength, gap formation, and mode of failure between endoscopic and open double-row gluteus medius repairs in a cadaveric model.Methods
Six pairs of fresh-frozen human cadavers were used in this study. Gluteus medius tears were created in an open fashion and then repaired with either open or endoscopic techniques. Specimens were manually preloaded to 5 N, then cycled between 20-50 N for 150 cycles s. Then, a ramp to/s. Specimens were then returned to 10 N and ramped to failure at 1 mm/s. Gap formation and strengths of the construct were compared for the 2 techniques.Results
Biomechanical testing resulted in no significant differences in ultimate load (P = .86) or gap formation (P > .10) between groups. Ninety-two percent o
SUBMITTER: Flynn ME
PROVIDER: S-EPMC9042893 | biostudies-literature | 2022 Apr
REPOSITORIES: biostudies-literature